Ana içeriğe atla

HeartWare Bibliography

 
  1. Tuzun E, Roberts K, Cohn WE, Sargin M, Gemmato CJ, Radovancevic B, Frazier OH. In vivo evaluation of the HeartWare centrifugal ventricular assist device.Tex Heart Inst J 2007;34(4):406-11.

  2. Wood C, Maiorana A, Larbalestier R, Lovett M, Green G and O’Driscoll G. First successful bridge to myocardial recovery with a HeartWare HVAD. J Heart Lung Transplant 2008;27:695–7. http://www.jhltonline.org/article/S1053-2498(08)00247-7/abstract

  3. Thomas MD, Wood C, Lovett M, Dembo L, O'Driscoll Successful treatment of rotary pump thrombus with the glycoprotein IIb/IIIa inhibitor Tirofiban. J Heart Lung Transplant 2008;27:925–7. http://www.jhltonline.org/article/S1053-2498(08)00420-8/abstract

  4. Slaughter MS, Ising MS, Tamez D, O’Driscoll G, Voskoboynikov N, Bartoli CR, Koenig SC, Giridharan GA. Increase in circadian variation after continuous-flow ventricular assist device implantation. J Heart Lung Transplant 2010;29:695–7. http://www.jhltonline.org/article/S1053-2498(09)01527-7/abstract

  5. Wieselthaler GW, O’Driscoll G, Jansz P, Khaghani A, Strueber M. Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi- institutional trial. J Heart Lung Transplant 2010;29:1218–25.http://www.jhltonline.org/article/S1053-2498(10)00311-6/abstract

  6. LaRose J, Tamez D, Ashenuga M, Reyes C. Design concepts and principle of operation of the HeartWare ventricular assist system. ASAIO J 2010;56:285–9.http://journals.lww.com/asaiojournal/Fulltext/2010/07000/Design_Concepts_and_Principle_of_Operation_of_the.3.aspx

  7. Hayes HM, Dembo LG, Larbalestier R, O’Driscoll G. Management options to treat gastrointestinal bleeding in patients supported on rotary left ventricular assist devices: A single-center experience. Artificial Organs 2010;34(9):703–6.

  8. Meyer AL, Kugler C, Malehsa D, Haverich A, Strueber M. Patient satisfaction with the external equipment of implantable left ventricular assist devices. Artif Organs 2010;34:721–5.

  9. Mozes A, DeNofrio D, Pham DT, Homoud MK. Inappropriate ICD therapy due to electromagnetic interference in a patient with a HeartWareHVAD™ left ventricular assist device. Heart Rhythm 2011;8(5)778–80.

  10. Gregoric ID, Cohn WE, Frazier OH. Diaphragmatic implantation of the HeartWare ventricular assist device. J Heart Lung Transplant 2011;30:467–70.

  11. Strueber M, O’Driscoll G, Jansz P, Khaghani A, Levy WC, Wieselthaler G. Multicenter evaluation of an intrapericardial left ventricular assist system. J Am Coll Cardiol 2011;57;1375–82.http://content.onlinejacc.org/article.aspx?articleid=1144278

  12. Kiernan MS, Pham DT, DeNofrio D, Kapur NK. Management of HeartWare left ventricular assist device thrombosis using intracavitary thrombolytics. J ThoracCardiovascSurg 2011;142(3):712–4.

  13. Salamonsen RF, Mason DG, Ayre PJ. Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart. Artificial Organs 2011;35(3):E47–53.

  14. Baumwol J, Macdonald PS, Keogh AM, Kotlyar E, Spratt P, Jansz P, Hayward CS. Right heart failure and “failure to thrive” after left ventricular assist device: Clinical predictors and outcomes. J Heart Lung Transplant 2011;30(8):888–95.http://www.jhltonline.org/article/S1053-2498(11)00868-0/abstract

  15. Ghodsizad A, Kar BJ, Layolka P, Okur A, Gonzales J, Bara C, Ungerer MN, Karck M, Gregoric ID, Ruhparwar A. Less invasive off-pump implantation of axial flow pumps in chronic ischemic heart failure: Survival effects. J Heart Lung Transplant 2011;30(7):834–7.http://www.jhltonline.org/article/S1053-2498(11)00875-8/abstract

  16. Geidl L, Deckert Z, Zrunek P, Gottardi R, Sterz F, Weiselthaler G, Schima H. Intuitive use and usability of ventricular assist device peripheral components in simulated emergency conditions. Artificial Organs 2011;35(8):773–80.

  17. Aissaoui N, Paluszkiewicz L. Schulte-Eistrup S, Morshuis M, Gummert J. An atypical thrombus in the inflow cannula of the HeartWare left ventricular assist device. Ann Thorac Surg 2011;92(3):e57.http://ats.ctsnetjournals.org/cgi/content/extract/92/3/e57?maxtoshow=&hits=10&RESULTFORMAT=&author1=Aissaoui&fulltext=Heartware+Left+Ventricular+&searchid=1&FIRSTINDEX=0&sortspec=relevance&resourcetype=HWCIT

  18. Slaughter MS. Implantation of the HeartWare Left Ventricular Assist Device. Semin Thorac Cardiovasc Surg. 2011;23(3):245–7.

  19. Potapov EV, Schweiger M and Krabatsch T. Percutaneous balloon occlusion of a left ventricular assist device outflow cannula to facilitate evaluation of myocardial recovery. J of Heart Lung Transplant Vol 30, No 11, page 1300. November 2011.http://www.jhltonline.org/article/S1053-2498(11)01050-3/fulltext

  20. Popov AF, Hosseini MT, Zych B et al. Clinical Experience With HeartWare Left Ventricular Assist Device in Patients With End-Stage Heart Failure. Ann Thorac Surg. 2012 Mar;93(3):810–5.http://ats.ctsnetjournals.org/cgi/content/abstract/93/3/810?maxtoshow=&hits=10&RESULTFORMAT=&author1=Popov&fulltext=Heartware+Left+Ventricular+Assist+Device&andorexactfulltext=and&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=810&resourcetype=HWCIT

  21. Aissaoui N, Borgermann J, Gummert J and Morshuis M. HeartWare continuous-flow ventricular assist device thrombosis: The Bad Oeynhausen experience. Epub J Thorac and Cardiovas Surg 2012.

  22. Popov AF, Hosseini MT, Zych B et al. HeartWare Left Ventricular Assist Device Implantation Through Bilateral Anterior Thoracotomy. Ann Thorac Surg 2012;93:674–6.http://ats.ctsnetjournals.org/cgi/content/abstract/93/2/674?maxtoshow=&hits=10&RESULTFORMAT=&author1=Popov&fulltext=Heartware+Left+Ventricular+Assist+Device&andorexactfulltext=and&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=674&resourcetype=HWCIT

  23. Schmitto JD, Molitoris U, Haverich A and Strueber M. Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: Upper hemisternotomy combined with anterolateral thoracotomy. J Thorac Cardiovasc Surg 2012;143:511–513.http://www.jtcvsonline.org/article/S0022-5223(11)00822-1/fulltext

  24. Hayward C and Swartz M. The Evolution of Ventricular Assist Devices and the HeartWare Ventricular Assist System. European Cardiology, 2012;8(1):32–5.

  25. Gossman MS, Graham JD, Tamez D, Voskoboynikov N and Larose J. Evaluation of a Ventricular Assist Device: Stability Under X-Rays and Therapeutic Beam Attenuation. Epub ASAIO Journal 2012.http://journals.lww.com/asaiojournal/pages/default.aspx

  26. Soleimani B, Haouzi A, Manoskey A, Stephenson ER, El-Banayosy A, and Pae WE. Development of Aortic Insufficiency in Patients Supported with Continuous Flow Left Ventricular Assist Devices. Epub May 25 2012. ASAIO J. 2012 Jul–Aug;58(4):326-9. doi: 10.1097/MAT.0b013e318251cfff.http://journals.lww.com/asaiojournal/pages/default.aspx

  27. Potapov EV, Krabatsch T, Hübler M and Hetzer R. Subcostal approach for replacement of failing circulatory pumps. J Thorac Cardiovasc Surg 2012;144:1272.http://www.jtcvsonline.org/article/S0022-5223(12)00998-1/fulltext

  28. Ozbaran M, Yagdi T, Engin C, Nalbantgil S, Ayik F, Oguz E, Engin Y, Ozturk P. New circulatory support system: HeartWare. Transplant Proc. 2012 Jul;44(6):1726-8. PubMed PMID: 22841255.http://www.ncbi.nlm.nih.gov/pubmed/22841255

  29. Yagdi T, Oguz E, Engin C, Engin Y, Nalbantgil S, Zoghi M, Ozbaran M. Changing face of heart failure surgery. Transplant Proc. 2012 Jul;44(6):1729–31. PubMed PMID: 22841256.http://www.ncbi.nlm.nih.gov/pubmed/?term=Evaluation+of+changes+in+quality+of+life+among+Turkish+patients+undergoing+ventricular+assist+device+implantation

  30. Ozturk C, Ayik F, Oguz E, Ozturk P, Karapolat H, Balcioglu O, Yagdi T, Engin C, Ozbaran M. Evaluation of changes in quality of life among Turkish patients undergoing ventricular assist device implantation. Transplant Proc. 2012 Jul;44(6):1735–7. PubMed PMID: 22841258.http://www.ncbi.nlm.nih.gov/pubmed/?term=Evaluation+of+changes+in+quality+of+life+among+Turkish+patients+undergoing+ventricular+assist+device+implantation

  31. McDiarmid A, Gordon B, Wrightson N, Robinson-Smith N, Pillay T, Parry G, Schueler S, Macgowan GA. Hemodynamic, Echocardiographic, and Exercise-Related Effects of the HeartWare Left Ventricular Assist Device in Advanced Heart Failure. Congest Heart Fail. 2012 Jul 13. doi: 10.1111/j.1751-7133.2012.00302.x. [Epub ahead of print] PubMed PMID: 22804927.http://www.ncbi.nlm.nih.gov/pubmed/?term=Hemodynamic%2C+Echocardiographic%2C+and+Exercise-Related+Effects+of+the+HeartWare+Left+Ventricular+Assist+Device+in+Advanced+Heart+Failure

  32. Kamouh A, John R, Eckman P. Successful Treatment of Early Thrombosis of HeartWare Left Ventricular Assist Device With Intraventricular Thrombolytics. Ann Thorac Surg. 2012 Jul;94(1):281-3. PubMed PMID: 22734996.http://ats.ctsnetjournals.org/cgi/content/abstract/94/1/281?maxtoshow=&hits=10&RESULTFORMAT=&author1=Kamouh&fulltext=Heartware+left+ventricular+assist+device&andorexactfulltext=and&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=281&resourcetype=HWCIT

  33. Saeed D, Albert A, Kamiya H, et al. Five Days of No Anticoagulation or Antiplatelet Therapy and NovoSeven Administration in a HeartWare HVAD Patient. Artif Organs. 2012 May 20. doi:10.1111/j.1525-1594.2012.01473.x. [Epub ahead of print] PubMed PMID: 22607278.http://www.ncbi.nlm.nih.gov/pubmed/22607278

  34. Takeda K, Ahmad U, Malaisrie CS et al. Successful implantation of HeartWare HVAD left ventricular assist device with concomitant ascending and sinus of Valsalva aneurysms repair. J Artif Organs (2012) 15:204–206.

  35. Aaronson KD, Slaughter MS, Miller LW, McGee EC, Cotts WG, Acker MA, Jessup ML, Gregoric ID, Loyalka P, Frazier OH, Jeevanandam V, Anderson AS, Kormos RL, Teuteberg JJ, Levy WC, Naftel DC, Bittman RM, Pagani FD, Hathaway DR, Boyce SW; for the HeartWare Ventricular Assist Device (HVAD) Bridge to Transplant ADVANCE Trial Investigators. Use of an Intrapericardial, Continuous-Flow, Centrifugal Pump in Patients Awaiting Heart Transplantation. Circulation. 2012 Jun 26;125(25):3191–3200. Epub 2012 May 22. PubMed PMID: 22619284.http://circ.ahajournals.org/content/125/25/3191.abstract?sid=695ad1d8-2ab2-4f4a-9b84-287cde7023db

  36. Granegger M, Moscato F, Casas F, Wieselthaler G and Schima H. Development of a Pump Flow Estimator for Rotary Blood Pumps to Enhance Monitoring of Ventricular Function. Artificial Organs 2012, 36(8):691–699.http://journals.lww.com/asaiojournal/pages/default.aspx

  37. Schweiger M, Potapov E, Vierecke J, Stepanenko A, Hetzer R and Krabatsch T. Expeditious and Less Traumatic Explantation of a HeartWare LVAD After Myocardial Recovery. ASAIO Journal 2012;58:542–544.

  38. Shah NR, MD, Cevik C, Hernandez A, Gregoric I, Frazier OH and Stainback RF. Transthoracic Echocardiography of the HeartWare Left Ventricular Assist Device. J Cardiac Fail 2012;18:745–748.http://www.onlinejcf.com/article/S1071-9164(11)00409-X/fulltext

  39. Saplacan V, Caprio S, Belin A and Buklas D. Ascending aorta thrombosis in a HeartWare® left ventricular assist device recipient. Eur J Cardiothorac Surg. 2012 Sep 26. [Epub ahead of print] PubMed PMID: 23014968.http://ejcts.oxfordjournals.org/content/43/1/e27.full?sid=a71ecb6f-e70b-4831-b36e-fb5d1f90d56d

  40. Garbade J, Bittner HB, Mohr FW and Barten MJ. Fluoroscopy-Guided Resolution of Ingested Thrombus Leading to Functional Disturbance of a Continuous-Flow LVAD. Case Reports in Surgery. Volume 2012, Article ID 791056, doi:10.1155/2012/791056.

  41. Santise G, Sciacca S, Baglini R, Clemenza F and Pilato M. Can Learning to Interpret Pump Messages Help Lead to an Early Diagnosis of HeartWare Ventricular Assist Device Thrombosis? ASAIO Journal 2012;58:629–632.http://journals.lww.com/asaiojournal/pages/default.aspx

  42. Mohite PN, Popov AF, Mittal TK and Simon AR. Tunneling of ventricular assist device outflow graft rostral to superior vena cava. J Thorac Cardiovasc Surg 2012;144:1519–1520.http://jtcs.ctsnetjournals.org/cgi/content/full/144/6/1519?maxtoshow=&hits=10&RESULTFORMAT=&author1=Mohite&fulltext=Tunneling+of+ventricular+assist+device&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=1519&resourcetype=HWCIT

  43. Carrel T, Englberger L, Martinelli MV, Takala J, Boesch C, Sigurdadottir V, Gygax E, Kadner A, Mohacsi P. Continuous flow left ventricular assist devices: a valid option for heart failure patients. Swiss Med Wkly. 2012 Oct 18;142:0. doi: 10.4414/smw.2012.13701.

  44. Sajjad M, Butt T, Oezalp, Siddique A, Wrightson N, Crawford D, Pillay T and Schueler S. An alternative approach to explantation and exchange of the HeartWare left ventricular assist device. Eur J Cardiothorac Surg (2012) 1–4 doi:10.1093/ejcts/ezs585.http://ejcts.oxfordjournals.org/content/early/2012/11/21/ejcts.ezs585.abstract?sid=8c4f2b4e-11da-4c32-a4e2-032c3144c7ea

  45. Palmen M, Verwey HF, Haeck ML. Implantation of a Left Ventricular Assist Device in Patients With a Complex Apical Anatomy. Ann Thorac Surg 2012;94:2122–2125.http://ats.ctsnetjournals.org/cgi/content/abstract/94/6/2122?maxtoshow=&hits=10&RESULTFORMAT=&author1=Palmen&fulltext=Left+Ventricular+Assist+Device&andorexactfulltext=and&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=2122&resourcetype=HWCIT

  46. Formica F. HeartWare LVAD Is a Promising Device for Patients With End-Stage Heart Failure. Ann Thorac Surg 2012;94:2176–83.

  47. Gossman MS, Graham JD, Das IJ, Cheng CW, Coutinho L, Tamez D, Larose JA. Evaluation of a ventricular assist device system: stability in a proton beam therapy. ASAIO J. 2012 Nov-Dec;58(6):597-600. doi: 10.1097/MAT.0b013e31826feeca. PubMed PMID: 23103698.http://journals.lww.com/asaiojournal/pages/default.aspx

  48. Meyer AL, Malehsam D, Bara C, Haverich A and Strueber M. Implantation of rotary blood pumps into 115 patients: a single-centre experience. Eur J Cardiothorac Surg Advance Access published December 9, 2012.http://ejcts.oxfordjournals.org/content/early/2012/12/09/ejcts.ezs568.abstract?sid=bdb1b9d1-0db9-4c05-857b-e482ab4d75e8

  49. Mohite PN, Bowles CT and Simon AR. A novel drive-line handling tool for the HeartWare ventricular assist device In patients with a physical disability. J of Heart Lung Transplant: Vol 31; No12, page 1323 December 2012.http://www.jhltonline.org/article/S1053-2498(12)01300-9/fulltext

  50. Moazami K, Fukamachi K, Kobayashi M et al. Axial and centrifugal continuous-flow rotary pumps A translation from pump mechanics to clinical practice. J Heart Lung Transplant 2013;32:1–11.http://www.jhltonline.org/article/S1053-2498(12)01358-7/abstract

  51. Abdul Jabbar AH, EtheridgeII WB II and Frazier OH. HeartWare implantation in a patient with situs inversus totalis. Epub - J Heart Lung Transplant Dec 2012.http://www.jhltonline.org/article/S1053-2498(12)01416-7/fulltext

  52. Dell’Aquila AM, Schneider SRB, Schlarb D et al. Initial Clinical Experience With the HeartWare Left Ventricular Assist System: A Single-Center Report. Ann Thorac Surg 2013;95:170–8.http://ats.ctsnetjournals.org/cgi/content/abstract/95/1/170?maxtoshow=&hits=10&RESULTFORMAT=&author1=Dell%27Aquila&fulltext=HeartWare+&andorexactfulltext=and&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=170&resourcetype=HWCIT

  53. Kirklin J. Invited Commentary on Initial Clinical Experience With the HeartWare LVAS A Single-Center Report. Ann Thorac Surg 2013;95:177–178.

  54. Huang J and Slaughter MS. HeartWare VAD placement in a patient with congenitally corrected transposition of the great arteries. Jour of Thorac and Cardiovasc Surg Volume 145, Number 2 e23.http://jtcs.ctsnetjournals.org/cgi/content/full/145/2/e23?maxtoshow=&hits=10&RESULTFORMAT=&author1=Huang&fulltext=HeartWare&searchid=1&FIRSTINDEX=0&sortspec=relevance&volume=145&resourcetype=HWCIT

  55. Labedi MR, Alharethi R, Kfoury AG, Budge D, Bruce R, Rasmusson B and Bunch JT. Electromagnetic Interference of Automatic Implantable Cardioverter Defibrillator and HeartWare LVAD. ASAIO Journal 2013;59:136–139.http://journals.lww.com/asaiojournal/pages/default.aspx

  56. Abicht T, Gordon R, Meehan K, Stosor V, McCarthy P and McGee E Jr. Complex HeartMate II Infection Treated with Pump Exchange to HeartWare HVAD. ASAIO Journal 2013;59:188–192.http://journals.lww.com/asaiojournal/pages/default.aspx

  57. Muthiah K, Phan J, Robson D et al. Centrifugal Continuous-Flow LVAD in Patients With Hypertrophic Cardiomyopathy A Case Series. ASAIO Journal 2013;59:183–187.http://journals.lww.com/asaiojournal/pages/default.aspx

  58. Hosseini MT, Popov AF, Simon AR, Amrani M, Bahrami T. Comparison of left ventricular geometry after HeartMate II and HeartWare left ventricular assist device implantation. J Cardiothorac Surg. 2013 Feb 28;8(1):31. [Epub ahead of print] PubMed PMID: 23445831.http://www.cardiothoracicsurgery.org/content/8/1/31/abstract

  59. Melisurgo G, De Bonis M, Pieri M, Nisi T, Silvetti S, Zangrillo A, Pappalardo F. Is flow really continuous in last generation continuous flow Ventricular Assist Devices? A comparison between HeartMate II and HeartWare HVAD. HSR Proc Intensive Care Cardiovasc Anesth. 2012;4(4):268-9. PubMed PMID: 23441288.77.http://www.ncbi.nlm.nih.gov/pubmed/?term=.+Is+flow+really+continuous+in+last+generation+continuous+flow+Ventricular+Assist+Devices%3F+A+comparison+between+HeartMate+II+and+HeartWare+HVAD

  60. García Sáez D, Mohite P, Zych B, Sabashnikov A, Simon AR. Successful replacement of a HeartAssist 5 ventricular assist device with a HeartWare without removal of the original sewing/attachment rings: how to do it. Interact Cardiovasc Thorac Surg. 2013 Feb 26. [Epub ahead of print] PubMed PMID: 23442940.http://www.ncbi.nlm.nih.gov/pubmed/?term=Successful+replacement+of+a+HeartAssist+5+ventricular+assist+device+with+a+HeartWare+without+removal+of+the+original+sewing%2Fattachment+rings%3A+how+to+do+it

  61. Kutty RS, Parameshwar J, Lewis C, Catarino PA, Sudarshan CD, Jenkins DP, Dunning JJ, Tsui SS. Use of centrifugal left ventricular assist device as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension. Eur J Cardiothorac Surg. 2013 Jan 22. [Epub ahead of print] PubMed PMID: 23345184.http://ejcts.oxfordjournals.org/content/early/2013/01/22/ejcts.ezs678.abstract?sid=0c84c4ad-aefb-42e9-9a5a-f0fcfa3123edx

  62. Jiritano F, Serraino GF, Cristodoro L and Renzulli A. Ventricular assist device abdominal driveline infection: Treatment with platelet-rich plasma. Epub. J Thorac Cardiovasc Surg 2013; – :1–2.

  63. Siddique A, Wrightson N, Macgowan GA and Schueler S. Device Thrombosis in the HeartWare Left Ventricular Assist Device. Letter To the Editor Ann Thorac Surg 2013;95:1507–14.

  64. Stulak JM, Cowger J, Haft JW, Romano HA, Aaronson KD and Pagani FP. Device Exchange After Primary Left Ventricular Assist Device Implantation: Indications and Outcomes. Ann Thorac Surg 2013;95:1262– 8).http://ats.ctsnetjournals.org/cgi/content/abstract/95/4/1262?maxtoshow=&hits=10&RESULTFORMAT=&author1=Stulak+JM&fulltext=Device+Exchange&andorexactfulltext=and&searchid=1&FIRSTINDEX=0&sortspec=relevance&firstpage=1262&resourcetype=HWCIT

  65. Slaughter MS, Pagani FD, McGee EC, Birks EJ, Cotts WG, Gregoric I, Frazier OH, Icenogle T, Najjar SS, Boyce SW, Acker MA, John R, Hathaway DR, Najarian KB, Aaronson KD. HeartWare ventricular assist system for bridge to transplant: Combined results of the bridge to transplant and continued access protocol trial. Epub. J Heart Lung Transplant 2013; 32:675-683.

  66. Shah NR, Lam WW, Rodriguez FH 3rd, Ermis PR, Simpson L, Frazier OH, Franklin WJ, Parekh DR. Clinical outcomes after ventricular assist device implantation in adults with complex congenital heart disease. J Heart Lung Transplant. 2013 Mar 26. doi:pii: S1053-2498(13)01169-8. 10.1016/j.healun.2013.03.003. [Epub ahead of print] PubMed PMID: 23540399. http://www.jhltonline.org/article/S1053-2498(13)01169-8/fulltext

  67. Morshuisa M, Boergermanna J, Gummerta J and Kosterb A. A modified technique for implantation of the HeartWare™ left ventricular assist device when using bivalirudin anticoagulation in patients with acute heparin-induced thrombocytopenia. Interactive CardioVascular and Thoracic Surgery (2013) 1–2 doi:10.1093/icvts/ivt187. http://icvts.oxfordjournals.org/content/17/2/225.full

  68. Balcioglu O, Engin C, Yagdi T, Nalbantgil S, Baysal B, Erkul S, Engin Y, Kutlayey I, and Ozbaran M. Effect of Aortic Valve Movements on Gastrointestinal Bleeding That Occurred in Continuous Flow Left Ventricular Assist Device Patients. Transplantation Proceedings, 45, 1020–1021 (2013). http://www.transplantation-proceedings.org/article/S0041-1345(13)00261-3/abstract

  69. Kocabas S, Askar FZ, Yagdi T, Engin C, and Ozbaran M. Anesthesia for Ventricular Assist Device Placement: Experience From a Single Center. Transplantation Proceedings, 45, 1005–1008 (2013). http://www.transplantation-proceedings.org/article/S0041-1345(13)00280-7/abstract

  70. Wu L, Weng YG, Dong NG, Krabatsch T, Stepanenko A, Hennig E, Hetzer R. Outcomes of HeartWare Ventricular Assist System support in 141 patients: a single-centre experience. Eur J Cardiothorac Surg. 2013 Apr 10. [Epub ahead of print] PubMed PMID: 22858453. http://ejcts.oxfordjournals.org/content/44/1/139.abstract

  71. Schima H, Schlöglhofer T, Hartner Z, Horvat J and Zimpfer D. Importance of linguistic details in alarm messages of ventricular assist devices. Int J Artif Organs 2013; 36(6): 406 - 409 published online 5/8/2013. http://www.artificial-organs.com/article/importance-of-linguistic-details-in-alarm-messages--of-ventricular-assist-devices

  72. Copeland J. HeartWare Ventricular Assist System for bridge to transplant The new kid on the block. Epub J Heart Lung Transplant/dx.doi.org/10.1016/j.healun.2013.04.008. http://www.jhltonline.org/article/S1053-2498(13)01212-6/fulltext

  73. Pennings KA, Martina JR, Rodermans BFM et al. Pump Flow Estimation From Pressure Head and Power Uptake for the HeartAssist 5, HeartMate II, and HeartWare VADs. ASAIO Journal. 59(4):420-426, July/August 2013. http://journals.lww.com/asaiojournal/Abstract/2013/07000/Pump_Flow_Estimation_From_Pressure_Head_and_Power.12.aspx

  74. Mohite PN, Zych B, Popov AR et al. Mitral commissurotomy through the left ventricle apical orifice with Heart Ware left ventricular assist device implantation. Journal of Cardiothoracic Surgery 2013, 8:147. http://www.cardiothoracicsurgery.org/content/8/1/147

  75. Garbade J, Barten MJ, Bittner HB and Mohr FW. Heart Transplantation and Left Ventricular Assist Device Therapy Two Comparable Options in End-Stage Heart Failure? Clin. Cardiol. 36, 7, 378–382 2013. http://onlinelibrary.wiley.com/doi/10.1002/clc.22124/full

  76. Lalonde SD, Alba AC, Rigobon A et al. Clinical Differences Between Continuous Flow Ventricular Assist Devices: A Comparison Between HeartMate II and HeartWare HVAD. doi: 10.1111/jocs.12158 (J Card Surg 2013;XX:1–7). http://onlinelibrary.wiley.com/doi/10.1111/jocs.12158/abstract

  77. Sabashnikov A, Mohite PN, Simon AR and Popov AF. HeartWare Miniaturized Intrapericardial VAD Advantages and Adverse Events in Comparison to Contemporary Devices. Expert Rev. Med. Devices 10(4), 441–452 (2013). http://www.expert-reviews.com/doi/abs/10.1586/17434440.2013.811851?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%3dpubmed&

  78. Akan A, Rogers CA, Parameshwar J, MacGowan G, Taylor R, Yonan N, Simon A, Tsui S, Schueler S and Banner NR on behalf of the Steering Group of the UK Cardiothoracic Transplant Audit and the UK VAD Forum. Trends in long-term mechanical circulatory support for advanced heart failure in the UK. European Journal of Heart Failure doi:10.1093/eurjhf/hft127. Published online July 30, 2013. http://eurjhf.oxfordjournals.org/content/15/10/1185.abstract

  79. Mohite PN, Popov AF, Sabashnikov A and Simon AR. HeartWare ventricular assist device experience in the real world. Letter to the Editor. European Journal of Cardio-Thoracic Surgery (2013) doi:10.1093/ejcts/ezt365. http://ejcts.oxfordjournals.org/content/early/2013/08/06/ejcts.ezt365.extract

  80. Bartoli CR, Vessels KM, McCants KC. Increased Intrathoracic Impedance May Predict Adverse Events in LVAD Patients. J Card Surg. 2013 Aug 4. doi:10.1111/jocs.12191. [Epub ahead of print] PubMed PMID: 23909444. http://onlinelibrary.wiley.com/doi/10.1111/jocs.12191/abstract

  81. Jabbar AA, Yau R, Frazier OH and Delgado R. Direct Thrombolytic Therapy for Thrombosis of a Centrifugal Flow Left Ventricular Assist Device. ASAIO Journal 2013; 59:530–532. http://journals.lww.com/asaiojournal/Abstract/2013/09000/Direct_Thrombolytic_Therapy_for_Thrombosis_of_a.16.aspx

  82. Dalén M, Sartipy U, Lund LH, Fux T, Corbascio M, Svenarud P, Grinnemo KH. Peripheral Extracorporeal Membrane Oxygenation as Short-Term Right Ventricular Support After HeartWare Left Ventricular Assist Device Implantation. ASAIO J. 2013 Sep-Oct;59(5):523-5. doi: 10.1097/MAT.0b013e31829be043. PubMed PMID:23851453. http://journals.lww.com/asaiojournal/Abstract/2013/09000/Peripheral_Extracorporeal_Membrane_Oxygenation_as.13.aspx

  83. Schweiger M, Dave H, Lemme F, Romanchenko O, Hofmann M, Hübler M. Ventricular assist devices: initial orientation. J Thorac Dis. 2013 Aug;5(4):567-71. doi:10.3978/j.issn.2072-1439.2013.08.12. PubMed PMID: 23991317; PubMed Central PMCID:PMC3755664. http://www.jthoracdis.com/article/view/1426/html